    Energy-saving terminal, ESS 100, Dialock

    • Energy control terminal with standard design

    • Energy control terminal

    • Space requirement flush-mount socket

    Note: The image may show a similar article

    Article details

    Area of application

    Mains operated

    Material

    Plastic

    Functionality

    Activation of electric circuits and switching of electrical devices with the aid of Dialock keys in ISO credit card size via integrated switching contact.
    Activation takes place for as long as a Dialock key is inserted into the holder of the energy control terminal.
    The passive ESS 100 can activate electric circuits.
    The inserted card is not recognised as a transponder and is not read out.
    Card holder authorisations are not taken into consideration.
    Every card is authorised.

    Installation reference

    Notes on operation and installation

    We recommend the use of an additional installation control relay for switching the electrical consumers.

    If a turn-off delay is required, a time delay relay must be provided.

    Installation of the energy control terminal in flush-mount socket with 2 device fastening screws (distance 60 mm in accordance with DIN)
    Ensure that screw points are horizontal.

    Order reference

    Options (please order separately)
    -Also available in design versions

    Supplied with

    1 ESS 100 energy control terminal with standard design, with frame

    Additional information attributes

    Notes for operation and installationWe recommend the use of an additional installation control relay for switching the electrical loads.
    If a turn-off delay is required, a time delay relay must be installed.
    Installation of the energy control terminal in flush-mount socket with 2 device fastening screws (distance 60 mm in compliance with DIN).
    Make sure the fastening points on the flush-mount socket are horizontal.